IFC certification

Fire resistance is a complete system, not simply a door.

Certified manufacture and installation, with each project assessed against the approved system, compatible components and installation requirements.

Performance depends on every element of the system.

Woodline holds IFC certification for the manufacture and installation of fire-rated doors. Each door must follow the documentation for the specific approved system; the certification does not mean that every Woodline door is fire-rated.

Manufacturing certificates IFCC 1812, IFCC 1813 and IFCC 1814, together with installer certificate IFCC 4045, have been verified. Performance applies exclusively within the scope and limitations of the corresponding assessment reports.

Elements considered

Specifications are assessed as a complete assembly and confirmed for the particular project.

  • Compatible door leaf and frame
  • Intumescent strips and smoke seals
  • Approved ironmongery
  • Frame-to-wall connection
  • Suitable fire-rated sealing materials

Pre- and post-installation checks

Opening inspection before fitting, recording of critical installation details and a final inspection where required.

Documentation

Installation records and client certificates may be provided where applicable to the approved system and scope of work.

IFC certification

Woodline certification for fire-rated door manufacture.

Certified installation

Certified scope for fire-rated door application and installation.

Approved system

Manufacture and installation in accordance with the covered system requirements.

Controlled documentation

Exact details and classifications will be published after current documents are verified.

Certified manufacturing and installation scope.

The certificates are issued by IFC Certification Ltd, part of the Kiwa UK Group. Their validity depends on continuing compliance, surveillance and the limitations of the referenced reports.

IFCC 1812Issue 3

Timber fire door manufacture - BS

Halspan FD30, FD60, FD90 and FD120; FireBAN FD30, FD60, FD90 and FD120; Strebord FD30 and FD60. Certified integrity from 30 to 120 minutes, within the parameters of the referenced reports.

Standards / scheme
SDP 01 v3.9 · BS 476: Part 22: 1987
Valid to
27/02/2028
View full certificate
IFCC 1813Issue 3

Timber fire door manufacture - EN

Halspan EI30 and EI60; Strebord EI30 and EI60. Certified integrity and insulation for 30 or 60 minutes, within the parameters of the referenced reports.

Standards / scheme
SDP 01 v3.9 · BS EN 1634-1:2014+A1:2018
Valid to
27/02/2028
View full certificate
IFCC 1814Issue 3

Fire-resistant glazed screen manufacture

Fire-resisting timber elements using 7 mm Pyroguard EW30 and 11 mm Pyroguard Maxi EW30/EW60. Fields of application for 30 to 60 minutes integrity in accordance with CF257.

Standards / scheme
SDP 09 v1.2 · BS 476-22 · BS EN 1363-1:2020 · BS EN 1364-1:2015
Valid to
27/02/2028
View full certificate
IFCC 4045Issue 1

Certificated installer of passive fire protection

Certified installation of timber doors, including quality-control-system assessment, competency assessment and continuing surveillance with random site audits.

Standards / scheme
SDI 00 v1.10 · SDI 14 v1.7 · Timber Doors
Valid to
19/10/2030
View full certificate

Each certificate should also be verified in the official IFC register. Performance classifications apply only to the precise specifications and parameters of the corresponding assessment reports. Official IFC verification.